| nx1 6500-48 | nx1 6500-48 US |
Inverter
| Continuous power @25°C | 4 500 VA | 4 500 VA |
| Power 30 min. @25°C | 6 500 VA | 6 500 VA |
| Power 5 sec. @25°C | 12 000 VA | 12 000 VA |
| Nominal line to neutral output voltage | pure sine wave 220/230/240 Vac (±1%) | Pure sine wave 110/120/130 Vac (±1%) |
| Nominal output frequency | 50/60 Hz (±0.02%) | 60/50 Hz (±0.02%) |
| Loads cosφ range | 0.1 – 1 | |
| Harmonic distorsion (THD) | < 1% | |
Battery charger
| Nominal battery voltage (Input range) | 48 Vdc (38 – 68 Vdc) |
| Maximum charging current / power* | 125 Adc | 125 Adc |
| Charge characteristic | 6 steps: bulk, absorption, floating, equalization, reduced floating, periodic absorption |
| Temperature compensation | with nx tempsensor (included) |
AC source (*Grid or Genset)
| Maximum rated current | 80 Aac |
| Operating line to neutral voltage range | 176 – 288 Vac |
| Nominal line to neutral voltage | 220 / 230 / 240 Vac |
| Nominal frequency* | 50 / 60 Hz |
| Overvoltage category (OVC) | III |
| Grid code compliance* | EU Commission Regulation 2016/631 (NC RfG), EN 50549-1:2019, VDE-AR-N 4105:2018, IEC 62116, IEC 61727 |
AC flex (*Controlled 2nd AC load or Genset)
| Maximum rated current | 50 Aac | |
| Operating line to neutral voltage range | 176 – 288 Vac | 60 – 150 Vac |
| Nominal line to neutral voltage | 220 / 230 / 240 Vac | 110 / 120 / 130 Vac |
| Nominal frequency | 50 / 60 Hz | 60 / 50 Hz |
General data
5 to 95 % (non condensing)
| Product dimensions h/w/l and weight | 182 / 439 / 580 mm 35 kg |
| Transport dimensions h/w/l and weight | NYA |
| Selfconsumption OFF / Standby / ON | 3 / 7 / 20 W |
| I/O Communications | 2 x nx communication bus RJ45/8, 1 x CAN BMS, 1 x RS485i (Modbus), 1 x nx tempSensor |
| Multifunction I/O contacts | 2 x digital Input, 2 x analogical Input, 2 x Aux output rating 16 A each |
| Interfaces | nx interface, datalogger USB 1-min resolution, 1 x RS485i, 1 x LAN, 2 x USB, nx wifidongle, studer portal + easy monitoring App |
| Safety+EMC conformity (CE marking) | EU Low Voltage Directive (LVD) 2014/35/EU, EU Electromagnetic Compliance (EMC) 2014/30/EU |
| Ingress Protection according to IEC60529 | IP 65 |

Inverter
| Continuous power @25°C | 15000 VA |
| Power 30 min. @25°C | 16000 VA |
| Power 5 sec. 25°C with solar / inverter / 1-phase | 30000 / 24000 / 10000 VA |
| Nominal output voltage, line to neutral* | pure sine wave 220/230/240 Vac (±1%) |
| Nominal output voltage, line to line* | pure sine wave 380/400/415 Vac (±1%) |
| Nominal output frequency* | 50/60 Hz (±0.02%) |
| Nominal battery voltage (Input range) | 48 Vdc (36 – 68 Vdc) |
| Maximum charging current / power* | 300 Adc / 15000 W |
Solar PV
| Number of MPPT inputs | 2 |
| Maximum PV short circuit current per PV input | 27 Adc |
| Maximum PV open voltage (Voc) | 900 Vdc |
| Start up voltage / Shut off voltage | 200 / 100 Vdc |
| Maximum solar power produced (electronic limitation) | 2 x 8000 W |
| Maximum solar power recommended (@STC) | 2 x 12000 W |
| MPP voltage range recommended | 300 – 700 Vdc |
Transfer
AC source (*Grid or Genset)
| Maximum rated current | 3 x 80 Aac |
| Operating voltage range, line to neutral | 176 – 288 Vac |
| Nominal voltage, line to neutral / line to line* | 220 – 230 – 240 / 380 – 400 – 415 Vac |
| Nominal frequency* | 50 / 60 Hz |
| Overvoltage category (OVC), Grid code compliance* | III, EU Commission Regulation 2016/631 (NC RfG), EN 50549-1:2019, VDE-AR-N 4105:2018, IEC 62116, IEC 61727 |
AC flex (*Controlled 2nd AC load or Genset)
| Maximum rated current | 3 x 80 Aac |
| Operating voltage range, line to neutral | 176 – 288 Vac |
| Nominal voltage, line to neutral / line to line* | 220 – 230 – 240 / 380 – 400 – 415 Vac |
| Nominal frequency* | 50 / 60 Hz |
AC loads Sortie AC
| Maximum output current | 3 x 102 Aac |
General data
| Product dimensions h/w/l and weight | 320 / 450 / 760 mm 58 kg |
| Transport dimensions h/w/l and weight | 600 / 800 / 720 mm 72 kg |
| Selfconsumption OFF / Standby / ON | 6 / 7 / 41 W (+5 W with nx interface) |
| I/O Communications | 2 x nx communication bus RJ45/8, 1 x CAN BMS, 1 x RS485i (Modbus), 1 x nx tempSensor |
| Multifunction I/O contacts | 2 x Input, 2 x Output, rating 16 A each |
| Interfaces | nx interface, datalogger USB 1-min resolution, 1 x RS485i, 1 x CANi, 1 x LAN, 4 x USB, nx wifidongle, studer portal + easy monitoring App |
| Safety+EMC conformity (CE marking) | EU Low Voltage Directive (LVD) 2014/35/EU, EU Electromagnetic Compliance (EMC) 2014/30/EU |
Verwacht begin 2025

| nx1 6500-48 | nx1 6500-48 US |
Inverter
| Continuous power @25°C | 4 500 VA | 4 500 VA |
| Power 30 min. @25°C | 6 500 VA | 6 500 VA |
| Power 5 sec. @25°C | 12 000 VA | 12 000 VA |
| Nominal line to neutral output voltage | pure sine wave 220/230/240 Vac (±1%) | Pure sine wave 110/120/130 Vac (±1%) |
| Nominal output frequency | 50/60 Hz (±0.02%) | 60/50 Hz (±0.02%) |
| Loads cosφ range | 0.1 – 1 | |
| Harmonic distorsion (THD) | < 1% | |
Battery charger
| Nominal battery voltage (Input range) | 48 Vdc (38 – 68 Vdc) |
| Maximum charging current / power* | 125 Adc | 125 Adc |
| Charge characteristic | 6 steps: bulk, absorption, floating, equalization, reduced floating, periodic absorption |
| Temperature compensation | with nx tempsensor (included) |
AC source (*Grid or Genset)
| Maximum rated current | 80 Aac |
| Operating line to neutral voltage range | 176 – 288 Vac |
| Nominal line to neutral voltage | 220 / 230 / 240 Vac |
| Nominal frequency* | 50 / 60 Hz |
| Overvoltage category (OVC) | III |
| Grid code compliance* | EU Commission Regulation 2016/631 (NC RfG), EN 50549-1:2019, VDE-AR-N 4105:2018, IEC 62116, IEC 61727 |
AC flex (*Controlled 2nd AC load or Genset)
| Maximum rated current | 50 Aac | |
| Operating line to neutral voltage range | 176 – 288 Vac | 60 – 150 Vac |
| Nominal line to neutral voltage | 220 / 230 / 240 Vac | 110 / 120 / 130 Vac |
| Nominal frequency | 50 / 60 Hz | 60 / 50 Hz |
General data
5 to 95 % (non condensing)
| Product dimensions h/w/l and weight | 177 / 483 / 585 mm 35 kg |
| Transport dimensions h/w/l and weight | NYA |
| Selfconsumption OFF / Standby / ON | 3 / 7 / 20 W |
| I/O Communications | 2 x nx communication bus RJ45/8, 1 x CAN BMS, 1 x RS485i (Modbus), 1 x nx tempSensor |
| Multifunction I/O contacts | 2 x digital Input, 2 x analogical Input, 2 x Aux output rating 16 A each |
| Interfaces | nx interface, datalogger USB 1-min resolution, 1 x RS485i, 1 x LAN, 2 x USB, nx wifidongle, studer portal + easy monitoring App |
| Safety+EMC conformity (CE marking) | EU Low Voltage Directive (LVD) 2014/35/EU, EU Electromagnetic Compliance (EMC) 2014/30/EU |
| Ingress Protection according to IEC60529 | IP 30 |

System
| Continuous power @25°C | 15000 VA |
| Power 30 min. @25°C | 16000 VA |
| Power 5 sec. 25°C with solar / inverter / 1-phase | 30000 / 24000 / 10000 VA |
| Nominal battery voltage (Input range) | 48 Vdc (36 – 68 Vdc) |
| Maximum charging current / power* | 300 Adc / 15000 W |
AC source (Grid or genset)
| Max rated current | 3 x 80 Aac |
| Operating voltage range, line to neutral | 176 – 288 Vac |
| Nominal voltage, line to neutral / line to line* | 220 – 230 – 240 / 380 – 400 – 415 Vac |
| Nominal frequency* | 50 / 60 Hz |
Solar PV
| Number of MPPT inputs | 2 |
| Maximum PV short circuit current per PV input | 27 Adc |
| Maximum PV open voltage (Voc) | 900 Vdc |
| Start up voltage / Shut off voltage | 200 / 100 Vdc |
| Maximum solar power produced (electronic limitation) | 2 x 8000 W |
| Maximum solar power recommended (@STC) | 2 x 12000 W |
AC flex (*Controlled 2nd AC load or Genset)
| Max rated current | 3 x 80 Aac |
Battery (from 1 to 6 modules, min 3 modules recommended)
| Manufacturer, model | Weco, 5k3-xp rack LV |
| Module capacity | 5.3 kWh |
| Single module nominal voltage | 51.2 Vdc |
| Usable capacity | 100 Ah |
| Dimension | 550x430x155 mm |
| Weight | 57.3 kg |
General data
| Product dimensions h/w/l and weight | 1990±30 / 605 / 1050 mm 816 kg (with 6 battery units) |
| Selfconsumption OFF / Standby / ON | 6 / 7 / 41 W (+5 W with nx interface) |
| Multifunction I/O contacts | 2 x Input, 2 x Output, rating 16 A each |
| Interfaces | nx interface, datalogger USB 1-min resolution, 1 x RS485i, 1 x CANi, 1 x LAN, 4 x USB, nx wifidongle, studer portal + easy monitoring App |
| Safety+EMC conformity (CE marking) | EU Low Voltage Directive (LVD) 2014/35/EU, EU Electromagnetic Compliance (EMC) 2014/30/EU |
| Ingress Protection | IP54 |
| Temperature control | air cooling |

| xts 900-12 | xts 1200-24 | xts 1400-48 |
Inverter
| Nominal battery voltage (Input range) | 12 Vdc | 24 Vdc | 48 Vdc |
| Continuous power @25°C | 650(1)/ 500 VA | 800(1)/ 650 VA | 900(1)/ 750 VA |
| Power 30 min. 25°C | 900(1)/ 700 VA | 1200(1)/ 1000 VA | 1400(1)/ 1200 VA |
| Power 5 sec. 25°C | 2.3 kVA | 2.5 kVA | 2.8 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%) / 120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.1/1.4/7 W | 1.2/1.5/8 W | 1.3/1.6/8 W |
Battery charger
| Maximum charging current(2) | 35 A | 25 A | 12 A |
Transfer
| Input voltage and frequency (2) | 150 to 265 Vac / 50 to 140 Vac (3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 16 Aac / 20 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 8.2 kg | 9 kg | 9.3 kg |
| Dimensions h/w/l [mm] | 110/210/310 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |

| xtm 2600-48 | xtm 3500-24 | xtm 4000-48 |
Inverter
| Nominal battery voltage (Input range) | 48 Vdc (38 – 60 Vdc) | 24 Vdc (19 – 34 Vdc) | 48 Vdc (38 – 60 Vdc) |
| Continuous power @25°C | 2000 VA | 3000 VA | 3500 VA |
| Power 30 min. 25°C | 2600 VA | 3500 VA | 4000 VA |
| Power 5 sec. 25°C | 6.5 kVA | 9 kVA | 10.5 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.8 / 2 / 10 W | 1.4 / 1.6 / 12 W | 1.8 / 2.1 / 14 W |
Battery charger
| Maximum charging current(2) | 30 A | 90 A | 50 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 16.2 kg | 21.2 kg | 22.9 kg |
| Dimensions h/w/l [mm] | 133 / 322 / 466 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xtm 1500-12 | xtm 2000-12 | xtm 2400-24 |
Inverter
| Nominal battery voltage (Input range) | 12 Vdc (9.5 – 17 Vdc) | 12 Vdc (9.5 – 17 Vdc) | 24 Vdc (19 – 34 Vdc) |
| Continuous power @25°C | 1500 VA | 2000 VA | 2000 VA |
| Power 30 min. 25°C | 1500 VA | 2000 VA | 2400 VA |
| Power 5 sec. 25°C | 3.4 kVA | 4.8 kVA | 6 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.2 / 1.4 / 8 W | 1.2 /1.4 / 10 W | 1.4 / 1.6 / 9 W |
Battery charger
| Maximum charging current(2) | 70 A | 100 A | 55 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 15 kg | 18.5 kg | 16.2 kg |
| Dimensions h/w/l [mm] | 133 / 322 / 466 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xtm 2600-48 | xtm 3500-24 | xtm 4000-48 |
Inverter
| Nominal battery voltage (Input range) | 48 Vdc (38 – 60 Vdc) | 24 Vdc (19 – 34 Vdc) | 48 Vdc (38 – 60 Vdc) |
| Continuous power @25°C | 2000 VA | 3000 VA | 3500 VA |
| Power 30 min. 25°C | 2600 VA | 3500 VA | 4000 VA |
| Power 5 sec. 25°C | 6.5 kVA | 9 kVA | 10.5 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.8 / 2 / 10 W | 1.4 / 1.6 / 12 W | 1.8 / 2.1 / 14 W |
Battery charger
| Maximum charging current(2) | 30 A | 90 A | 50 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 16.2 kg | 21.2 kg | 22.9 kg |
| Dimensions h/w/l [mm] | 133 / 322 / 466 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xtm 1500-12 | xtm 2000-12 | xtm 2400-24 |
Inverter
| Nominal battery voltage (Input range) | 12 Vdc (9.5 – 17 Vdc) | 12 Vdc (9.5 – 17 Vdc) | 24 Vdc (19 – 34 Vdc) |
| Continuous power @25°C | 1500 VA | 2000 VA | 2000 VA |
| Power 30 min. 25°C | 1500 VA | 2000 VA | 2400 VA |
| Power 5 sec. 25°C | 3.4 kVA | 4.8 kVA | 6 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.2 / 1.4 / 8 W | 1.2 /1.4 / 10 W | 1.4 / 1.6 / 9 W |
Battery charger
| Maximum charging current(2) | 70 A | 100 A | 55 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 15 kg | 18.5 kg | 16.2 kg |
| Dimensions h/w/l [mm] | 133 / 322 / 466 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |

| xth 6000-48 | xth 8000-48 |
Inverter
| Nominal battery voltage (Input range) | 48 Vdc (38 – 60 Vdc) | 48 Vdc (38 – 60 Vdc) |
| Continuous power @25°C | 5000 VA | 7000 VA |
| Power 30 min. 25°C | 6000 VA | 8000 VA |
| Power 5 sec. 25°C | 15 kVA | 21 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.8 / 2.2 / 22 W | 1.8 / 2.4 / 30 W |
Battery charger
| Maximum charging current(2) | 100 A | 120 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac | 50 Aac / 80 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 42 kg | 46 kg |
| Dimensions h/w/l [mm] | 230/300/500 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xth 3000-12 | xth 5000-24 |
Inverter
| Nominal battery voltage (Input range) | 12 Vdc (9.5 – 17 Vdc) | 24 Vdc (19 – 34 Vdc) |
| Continuous power @25°C | 2500 VA | 4500 VA |
| Power 30 min. 25°C | 3000 VA | 5000 VA |
| Power 5 sec. 25°C | 7.5 kVA | 12 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.2 / 1.4 / 14 W | 1.4 / 1.8 / 18 W |
Battery charger
| Maximum charging current(2) | 160 A | 140 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 34 kg | 40 kg |
| Dimensions h/w/l [mm] | 230/300/500 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xth 6000-48 | xth 8000-48 |
Inverter
| Nominal battery voltage (Input range) | 48 Vdc (38 – 60 Vdc) | 48 Vdc (38 – 60 Vdc) |
| Continuous power @25°C | 5000 VA | 7000 VA |
| Power 30 min. 25°C | 6000 VA | 8000 VA |
| Power 5 sec. 25°C | 15 kVA | 21 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.8 / 2.2 / 22 W | 1.8 / 2.4 / 30 W |
Battery charger
| Maximum charging current(2) | 100 A | 120 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac | 50 Aac / 80 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 42 kg | 46 kg |
| Dimensions h/w/l [mm] | 230/300/500 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xth 3000-12 | xth 5000-24 |
Inverter
| Nominal battery voltage (Input range) | 12 Vdc (9.5 – 17 Vdc) | 24 Vdc (19 – 34 Vdc) |
| Continuous power @25°C | 2500 VA | 4500 VA |
| Power 30 min. 25°C | 3000 VA | 5000 VA |
| Power 5 sec. 25°C | 7.5 kVA | 12 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.2 / 1.4 / 14 W | 1.4 / 1.8 / 18 W |
Battery charger
| Maximum charging current(2) | 160 A | 140 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 34 kg | 40 kg |
| Dimensions h/w/l [mm] | 230/300/500 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
Low and high voltage solar charge controllers

Small applications
(0.6 – 2.5 kW)
IP54, outdoor and indoor
Battery voltage options 12, 24, 48V
150V PV input voltage
Reliable, LV safety
Compatible with different battery technologies (lead-acid, lithium)
Combine with xtender battery invertes

The most versatile
(1 – 5 kW)
IP54, outdoor and indoor
Battery voltage options 12, 24, 48V
150V PV input voltage
Reliable, LV safety
Compatible with different battery technologies (lead-acid, lithium)
Combine with xtender battery invertes

Compact performance (4.2kW)
IP54, outdoor and indoor
48V battery voltage
High PV input voltage
(600V)
Reduced balance of system
Compatible with different battery technologies (lead-acid, lithium)
Combine with xtender battery invertes

High performance (7kW)
IP20, indoor
48V battery voltage
High PV input voltage
(600-900V)
Reduced balance of system
Compatible with different battery technologies (lead-acid, lithium)
Combine with xtender battery invertes
Pure sine wave inverter

275 – 400 VA
Standby only with solar option
Battery voltage options 12, 24, 48V
Remote control (rcm 01, 02, 03)
Battery lifetime optimization (BLO) function
Optional PWM built-in solar regulator
Optional 120V, 50-60Hz

500 – 700 VA
Standby with the lowest selfconsumption from the market
Battery voltage options 12, 24, 48V
Remote control (rcm 01, 02, 03)
Battery lifetime optimization (BLO) function
Optional PWM built-in solar regulator
Optional 120V, 50-60Hz

1000 – 1300 VA
Standby with the lowest selfconsumption from the market
Battery voltage option 12, 24V
Remote control jt8
Battery lifetime optimization (BLO) function
Optional PWM built-in solar regulator
Optional 120V, 50-60Hz

2100 – 2400 VA
Standby with the lowest selfconsumption from the market
Battery voltage option 12, 24V
Remote control jt8
Battery lifetime optimization (BLO) function
Optional PWM built-in solar regulator
Optional 120V, 50-60Hz
Verwacht begin 2025
| nx1 6500-48 | nx1 6500-48 US |
Inverter
| Continuous power @25°C | 4 500 VA | 4 500 VA |
| Power 30 min. @25°C | 6 500 VA | 6 500 VA |
| Power 5 sec. @25°C | 12 000 VA | 12 000 VA |
| Nominal line to neutral output voltage | pure sine wave 220/230/240 Vac (±1%) | Pure sine wave 110/120/130 Vac (±1%) |
| Nominal output frequency | 50/60 Hz (±0.02%) | 60/50 Hz (±0.02%) |
| Loads cosφ range | 0.1 – 1 | |
| Harmonic distorsion (THD) | < 1% | |
Battery charger
| Nominal battery voltage (Input range) | 48 Vdc (38 – 68 Vdc) |
| Maximum charging current / power* | 125 Adc | 125 Adc |
| Charge characteristic | 6 steps: bulk, absorption, floating, equalization, reduced floating, periodic absorption |
| Temperature compensation | with nx tempsensor (included) |
AC source (*Grid or Genset)
| Maximum rated current | 80 Aac |
| Operating line to neutral voltage range | 176 – 288 Vac |
| Nominal line to neutral voltage | 220 / 230 / 240 Vac |
| Nominal frequency* | 50 / 60 Hz |
| Overvoltage category (OVC) | III |
| Grid code compliance* | EU Commission Regulation 2016/631 (NC RfG), EN 50549-1:2019, VDE-AR-N 4105:2018, IEC 62116, IEC 61727 |
AC flex (*Controlled 2nd AC load or Genset)
| Maximum rated current | 50 Aac | |
| Operating line to neutral voltage range | 176 – 288 Vac | 60 – 150 Vac |
| Nominal line to neutral voltage | 220 / 230 / 240 Vac | 110 / 120 / 130 Vac |
| Nominal frequency | 50 / 60 Hz | 60 / 50 Hz |
General data
5 to 95 % (non condensing)
| Product dimensions h/w/l and weight | 182 / 439 / 580 mm 35 kg |
| Transport dimensions h/w/l and weight | NYA |
| Selfconsumption OFF / Standby / ON | 3 / 7 / 20 W |
| I/O Communications | 2 x nx communication bus RJ45/8, 1 x CAN BMS, 1 x RS485i (Modbus), 1 x nx tempSensor |
| Multifunction I/O contacts | 2 x digital Input, 2 x analogical Input, 2 x Aux output rating 16 A each |
| Interfaces | nx interface, datalogger USB 1-min resolution, 1 x RS485i, 1 x LAN, 2 x USB, nx wifidongle, studer portal + easy monitoring App |
| Safety+EMC conformity (CE marking) | EU Low Voltage Directive (LVD) 2014/35/EU, EU Electromagnetic Compliance (EMC) 2014/30/EU |
| Ingress Protection according to IEC60529 | IP 65 |

Inverter
| Continuous power @25°C | 15000 VA |
| Power 30 min. @25°C | 16000 VA |
| Power 5 sec. 25°C with solar / inverter / 1-phase | 30000 / 24000 / 10000 VA |
| Nominal output voltage, line to neutral* | pure sine wave 220/230/240 Vac (±1%) |
| Nominal output voltage, line to line* | pure sine wave 380/400/415 Vac (±1%) |
| Nominal output frequency* | 50/60 Hz (±0.02%) |
| Nominal battery voltage (Input range) | 48 Vdc (36 – 68 Vdc) |
| Maximum charging current / power* | 300 Adc / 15000 W |
Solar PV
| Number of MPPT inputs | 2 |
| Maximum PV short circuit current per PV input | 27 Adc |
| Maximum PV open voltage (Voc) | 900 Vdc |
| Start up voltage / Shut off voltage | 200 / 100 Vdc |
| Maximum solar power produced (electronic limitation) | 2 x 8000 W |
| Maximum solar power recommended (@STC) | 2 x 12000 W |
| MPP voltage range recommended | 300 – 700 Vdc |
Transfer
AC source (*Grid or Genset)
| Maximum rated current | 3 x 80 Aac |
| Operating voltage range, line to neutral | 176 – 288 Vac |
| Nominal voltage, line to neutral / line to line* | 220 – 230 – 240 / 380 – 400 – 415 Vac |
| Nominal frequency* | 50 / 60 Hz |
| Overvoltage category (OVC), Grid code compliance* | III, EU Commission Regulation 2016/631 (NC RfG), EN 50549-1:2019, VDE-AR-N 4105:2018, IEC 62116, IEC 61727 |
AC flex (*Controlled 2nd AC load or Genset)
| Maximum rated current | 3 x 80 Aac |
| Operating voltage range, line to neutral | 176 – 288 Vac |
| Nominal voltage, line to neutral / line to line* | 220 – 230 – 240 / 380 – 400 – 415 Vac |
| Nominal frequency* | 50 / 60 Hz |
AC loads Sortie AC
| Maximum output current | 3 x 102 Aac |
General data
| Product dimensions h/w/l and weight | 320 / 450 / 760 mm 58 kg |
| Transport dimensions h/w/l and weight | 600 / 800 / 720 mm 72 kg |
| Selfconsumption OFF / Standby / ON | 6 / 7 / 41 W (+5 W with nx interface) |
| I/O Communications | 2 x nx communication bus RJ45/8, 1 x CAN BMS, 1 x RS485i (Modbus), 1 x nx tempSensor |
| Multifunction I/O contacts | 2 x Input, 2 x Output, rating 16 A each |
| Interfaces | nx interface, datalogger USB 1-min resolution, 1 x RS485i, 1 x CANi, 1 x LAN, 4 x USB, nx wifidongle, studer portal + easy monitoring App |
| Safety+EMC conformity (CE marking) | EU Low Voltage Directive (LVD) 2014/35/EU, EU Electromagnetic Compliance (EMC) 2014/30/EU |
Verwacht begin 2025

| nx1 6500-48 | nx1 6500-48 US |
Inverter
| Continuous power @25°C | 4 500 VA | 4 500 VA |
| Power 30 min. @25°C | 6 500 VA | 6 500 VA |
| Power 5 sec. @25°C | 12 000 VA | 12 000 VA |
| Nominal line to neutral output voltage | pure sine wave 220/230/240 Vac (±1%) | Pure sine wave 110/120/130 Vac (±1%) |
| Nominal output frequency | 50/60 Hz (±0.02%) | 60/50 Hz (±0.02%) |
| Loads cosφ range | 0.1 – 1 | |
| Harmonic distorsion (THD) | < 1% | |
Battery charger
| Nominal battery voltage (Input range) | 48 Vdc (38 – 68 Vdc) |
| Maximum charging current / power* | 125 Adc | 125 Adc |
| Charge characteristic | 6 steps: bulk, absorption, floating, equalization, reduced floating, periodic absorption |
| Temperature compensation | with nx tempsensor (included) |
AC source (*Grid or Genset)
| Maximum rated current | 80 Aac |
| Operating line to neutral voltage range | 176 – 288 Vac |
| Nominal line to neutral voltage | 220 / 230 / 240 Vac |
| Nominal frequency* | 50 / 60 Hz |
| Overvoltage category (OVC) | III |
| Grid code compliance* | EU Commission Regulation 2016/631 (NC RfG), EN 50549-1:2019, VDE-AR-N 4105:2018, IEC 62116, IEC 61727 |
AC flex (*Controlled 2nd AC load or Genset)
| Maximum rated current | 50 Aac | |
| Operating line to neutral voltage range | 176 – 288 Vac | 60 – 150 Vac |
| Nominal line to neutral voltage | 220 / 230 / 240 Vac | 110 / 120 / 130 Vac |
| Nominal frequency | 50 / 60 Hz | 60 / 50 Hz |
General data
5 to 95 % (non condensing)
| Product dimensions h/w/l and weight | 177 / 483 / 585 mm 35 kg |
| Transport dimensions h/w/l and weight | NYA |
| Selfconsumption OFF / Standby / ON | 3 / 7 / 20 W |
| I/O Communications | 2 x nx communication bus RJ45/8, 1 x CAN BMS, 1 x RS485i (Modbus), 1 x nx tempSensor |
| Multifunction I/O contacts | 2 x digital Input, 2 x analogical Input, 2 x Aux output rating 16 A each |
| Interfaces | nx interface, datalogger USB 1-min resolution, 1 x RS485i, 1 x LAN, 2 x USB, nx wifidongle, studer portal + easy monitoring App |
| Safety+EMC conformity (CE marking) | EU Low Voltage Directive (LVD) 2014/35/EU, EU Electromagnetic Compliance (EMC) 2014/30/EU |
| Ingress Protection according to IEC60529 | IP 30 |

System
| Continuous power @25°C | 15000 VA |
| Power 30 min. @25°C | 16000 VA |
| Power 5 sec. 25°C with solar / inverter / 1-phase | 30000 / 24000 / 10000 VA |
| Nominal battery voltage (Input range) | 48 Vdc (36 – 68 Vdc) |
| Maximum charging current / power* | 300 Adc / 15000 W |
AC source (Grid or genset)
| Max rated current | 3 x 80 Aac |
| Operating voltage range, line to neutral | 176 – 288 Vac |
| Nominal voltage, line to neutral / line to line* | 220 – 230 – 240 / 380 – 400 – 415 Vac |
| Nominal frequency* | 50 / 60 Hz |
Solar PV
| Number of MPPT inputs | 2 |
| Maximum PV short circuit current per PV input | 27 Adc |
| Maximum PV open voltage (Voc) | 900 Vdc |
| Start up voltage / Shut off voltage | 200 / 100 Vdc |
| Maximum solar power produced (electronic limitation) | 2 x 8000 W |
| Maximum solar power recommended (@STC) | 2 x 12000 W |
AC flex (*Controlled 2nd AC load or Genset)
| Max rated current | 3 x 80 Aac |
Battery (from 1 to 6 modules, min 3 modules recommended)
| Manufacturer, model | Weco, 5k3-xp rack LV |
| Module capacity | 5.3 kWh |
| Single module nominal voltage | 51.2 Vdc |
| Usable capacity | 100 Ah |
| Dimension | 550x430x155 mm |
| Weight | 57.3 kg |
General data
| Product dimensions h/w/l and weight | 1990±30 / 605 / 1050 mm 816 kg (with 6 battery units) |
| Selfconsumption OFF / Standby / ON | 6 / 7 / 41 W (+5 W with nx interface) |
| Multifunction I/O contacts | 2 x Input, 2 x Output, rating 16 A each |
| Interfaces | nx interface, datalogger USB 1-min resolution, 1 x RS485i, 1 x CANi, 1 x LAN, 4 x USB, nx wifidongle, studer portal + easy monitoring App |
| Safety+EMC conformity (CE marking) | EU Low Voltage Directive (LVD) 2014/35/EU, EU Electromagnetic Compliance (EMC) 2014/30/EU |
| Ingress Protection | IP54 |
| Temperature control | air cooling |

| xts 900-12 | xts 1200-24 | xts 1400-48 |
Inverter
| Nominal battery voltage (Input range) | 12 Vdc | 24 Vdc | 48 Vdc |
| Continuous power @25°C | 650(1)/ 500 VA | 800(1)/ 650 VA | 900(1)/ 750 VA |
| Power 30 min. 25°C | 900(1)/ 700 VA | 1200(1)/ 1000 VA | 1400(1)/ 1200 VA |
| Power 5 sec. 25°C | 2.3 kVA | 2.5 kVA | 2.8 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%) / 120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.1/1.4/7 W | 1.2/1.5/8 W | 1.3/1.6/8 W |
Battery charger
| Maximum charging current(2) | 35 A | 25 A | 12 A |
Transfer
| Input voltage and frequency (2) | 150 to 265 Vac / 50 to 140 Vac (3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 16 Aac / 20 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 8.2 kg | 9 kg | 9.3 kg |
| Dimensions h/w/l [mm] | 110/210/310 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |

| xtm 2600-48 | xtm 3500-24 | xtm 4000-48 |
Inverter
| Nominal battery voltage (Input range) | 48 Vdc (38 – 60 Vdc) | 24 Vdc (19 – 34 Vdc) | 48 Vdc (38 – 60 Vdc) |
| Continuous power @25°C | 2000 VA | 3000 VA | 3500 VA |
| Power 30 min. 25°C | 2600 VA | 3500 VA | 4000 VA |
| Power 5 sec. 25°C | 6.5 kVA | 9 kVA | 10.5 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.8 / 2 / 10 W | 1.4 / 1.6 / 12 W | 1.8 / 2.1 / 14 W |
Battery charger
| Maximum charging current(2) | 30 A | 90 A | 50 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 16.2 kg | 21.2 kg | 22.9 kg |
| Dimensions h/w/l [mm] | 133 / 322 / 466 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xtm 1500-12 | xtm 2000-12 | xtm 2400-24 |
Inverter
| Nominal battery voltage (Input range) | 12 Vdc (9.5 – 17 Vdc) | 12 Vdc (9.5 – 17 Vdc) | 24 Vdc (19 – 34 Vdc) |
| Continuous power @25°C | 1500 VA | 2000 VA | 2000 VA |
| Power 30 min. 25°C | 1500 VA | 2000 VA | 2400 VA |
| Power 5 sec. 25°C | 3.4 kVA | 4.8 kVA | 6 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.2 / 1.4 / 8 W | 1.2 /1.4 / 10 W | 1.4 / 1.6 / 9 W |
Battery charger
| Maximum charging current(2) | 70 A | 100 A | 55 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 15 kg | 18.5 kg | 16.2 kg |
| Dimensions h/w/l [mm] | 133 / 322 / 466 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xtm 2600-48 | xtm 3500-24 | xtm 4000-48 |
Inverter
| Nominal battery voltage (Input range) | 48 Vdc (38 – 60 Vdc) | 24 Vdc (19 – 34 Vdc) | 48 Vdc (38 – 60 Vdc) |
| Continuous power @25°C | 2000 VA | 3000 VA | 3500 VA |
| Power 30 min. 25°C | 2600 VA | 3500 VA | 4000 VA |
| Power 5 sec. 25°C | 6.5 kVA | 9 kVA | 10.5 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.8 / 2 / 10 W | 1.4 / 1.6 / 12 W | 1.8 / 2.1 / 14 W |
Battery charger
| Maximum charging current(2) | 30 A | 90 A | 50 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 16.2 kg | 21.2 kg | 22.9 kg |
| Dimensions h/w/l [mm] | 133 / 322 / 466 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xtm 1500-12 | xtm 2000-12 | xtm 2400-24 |
Inverter
| Nominal battery voltage (Input range) | 12 Vdc (9.5 – 17 Vdc) | 12 Vdc (9.5 – 17 Vdc) | 24 Vdc (19 – 34 Vdc) |
| Continuous power @25°C | 1500 VA | 2000 VA | 2000 VA |
| Power 30 min. 25°C | 1500 VA | 2000 VA | 2400 VA |
| Power 5 sec. 25°C | 3.4 kVA | 4.8 kVA | 6 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.2 / 1.4 / 8 W | 1.2 /1.4 / 10 W | 1.4 / 1.6 / 9 W |
Battery charger
| Maximum charging current(2) | 70 A | 100 A | 55 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 15 kg | 18.5 kg | 16.2 kg |
| Dimensions h/w/l [mm] | 133 / 322 / 466 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |

| xth 6000-48 | xth 8000-48 |
Inverter
| Nominal battery voltage (Input range) | 48 Vdc (38 – 60 Vdc) | 48 Vdc (38 – 60 Vdc) |
| Continuous power @25°C | 5000 VA | 7000 VA |
| Power 30 min. 25°C | 6000 VA | 8000 VA |
| Power 5 sec. 25°C | 15 kVA | 21 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.8 / 2.2 / 22 W | 1.8 / 2.4 / 30 W |
Battery charger
| Maximum charging current(2) | 100 A | 120 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac | 50 Aac / 80 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 42 kg | 46 kg |
| Dimensions h/w/l [mm] | 230/300/500 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xth 3000-12 | xth 5000-24 |
Inverter
| Nominal battery voltage (Input range) | 12 Vdc (9.5 – 17 Vdc) | 24 Vdc (19 – 34 Vdc) |
| Continuous power @25°C | 2500 VA | 4500 VA |
| Power 30 min. 25°C | 3000 VA | 5000 VA |
| Power 5 sec. 25°C | 7.5 kVA | 12 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.2 / 1.4 / 14 W | 1.4 / 1.8 / 18 W |
Battery charger
| Maximum charging current(2) | 160 A | 140 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 34 kg | 40 kg |
| Dimensions h/w/l [mm] | 230/300/500 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xth 6000-48 | xth 8000-48 |
Inverter
| Nominal battery voltage (Input range) | 48 Vdc (38 – 60 Vdc) | 48 Vdc (38 – 60 Vdc) |
| Continuous power @25°C | 5000 VA | 7000 VA |
| Power 30 min. 25°C | 6000 VA | 8000 VA |
| Power 5 sec. 25°C | 15 kVA | 21 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.8 / 2.2 / 22 W | 1.8 / 2.4 / 30 W |
Battery charger
| Maximum charging current(2) | 100 A | 120 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac | 50 Aac / 80 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 42 kg | 46 kg |
| Dimensions h/w/l [mm] | 230/300/500 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
| xth 3000-12 | xth 5000-24 |
Inverter
| Nominal battery voltage (Input range) | 12 Vdc (9.5 – 17 Vdc) | 24 Vdc (19 – 34 Vdc) |
| Continuous power @25°C | 2500 VA | 4500 VA |
| Power 30 min. 25°C | 3000 VA | 5000 VA |
| Power 5 sec. 25°C | 7.5 kVA | 12 kVA |
| Output voltage and frequency(2) | pure sine wave 230 Vac (± 2%)/120 Vac(3) and 45-65 Hz(3) ± 0.05% (crystal controlled) |
| Consumption OFF/Stand-by/ON | 1.2 / 1.4 / 14 W | 1.4 / 1.8 / 18 W |
Battery charger
| Maximum charging current(2) | 160 A | 140 A |
Transfer
| Input voltage and frequency(2) | 150 to 265 Vac / 50 to 140 Vac(3) and 45 to 65 Hz |
| Input current max. (transfer relay) / Output current max. | 50 Aac / 56 Aac |
| Transfer time | < 15 ms |
General data
| Weight | 34 kg | 40 kg |
| Dimensions h/w/l [mm] | 230/300/500 mm |
| Conformity | low voltage directive (LVD) 2014/35/EU: EN/IEC 62477-1, 62109-1, 62109-2, 62040-1, electromagnetic compliance (EMC) directive 2014/30/EU: EN/IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
Low and high voltage solar charge controllers

Small applications
(0.6 – 2.5 kW)
IP54, outdoor and indoor
Battery voltage options 12, 24, 48V
150V PV input voltage
Reliable, LV safety
Compatible with different battery technologies (lead-acid, lithium)
Combine with xtender battery invertes

The most versatile
(1 – 5 kW)
IP54, outdoor and indoor
Battery voltage options 12, 24, 48V
150V PV input voltage
Reliable, LV safety
Compatible with different battery technologies (lead-acid, lithium)
Combine with xtender battery invertes

Compact performance (4.2kW)
IP54, outdoor and indoor
48V battery voltage
High PV input voltage
(600V)
Reduced balance of system
Compatible with different battery technologies (lead-acid, lithium)
Combine with xtender battery invertes

High performance (7kW)
IP20, indoor
48V battery voltage
High PV input voltage
(600-900V)
Reduced balance of system
Compatible with different battery technologies (lead-acid, lithium)
Combine with xtender battery invertes
Pure sine wave inverter

275 – 400 VA
Standby only with solar option
Battery voltage options 12, 24, 48V
Remote control (rcm 01, 02, 03)
Battery lifetime optimization (BLO) function
Optional PWM built-in solar regulator
Optional 120V, 50-60Hz

500 – 700 VA
Standby with the lowest selfconsumption from the market
Battery voltage options 12, 24, 48V
Remote control (rcm 01, 02, 03)
Battery lifetime optimization (BLO) function
Optional PWM built-in solar regulator
Optional 120V, 50-60Hz

1000 – 1300 VA
Standby with the lowest selfconsumption from the market
Battery voltage option 12, 24V
Remote control jt8
Battery lifetime optimization (BLO) function
Optional PWM built-in solar regulator
Optional 120V, 50-60Hz

2100 – 2400 VA
Standby with the lowest selfconsumption from the market
Battery voltage option 12, 24V
Remote control jt8
Battery lifetime optimization (BLO) function
Optional PWM built-in solar regulator
Optional 120V, 50-60Hz
Niet alle items zijn standaard op voorraad. Voor actuele beschikbaarheid en prijzen kun je eenvoudig inloggen op ons partnerportaal.
Heb je vragen of zoek je een specifiek type? Neem gerust contact met ons op, we helpen je graag!
Prof. Eykmanweg 27
5144 ND Waalwijk
Telefoon +31 416 69 31 55
KvK nr.: 18057897
BTW nr.: NL808305487B01
Niet alle items zijn standaard op voorraad. Voor actuele beschikbaarheid en prijzen kun je eenvoudig inloggen op ons partnerportaal.
Heb je vragen of zoek je een specifiek type? Neem gerust contact met ons op, we helpen je graag!
Prof. Eykmanweg 27
5144 ND Waalwijk
Telefoon +31 416 69 31 55
KvK nr.: 18057897
BTW nr.: NL808305487B01
Algemene Voorwaarden | PRIVACY STATEMENT | COOKIES | DISCLAIMER | © 1995 - 2025 Alle rechten voorbehouden
Algemene Voorwaarden | PRIVACY STATEMENT | COOKIES | DISCLAIMER | © 1995 - 2025 Alle rechten voorbehouden